managing applications within a crestron 3-series processor

 

the 3-series processor brings a whole new set of console commands and parameters that go with them.

 

in the e-control web interface, you have the ability to register and start applications:

 

appManager

 

register – find the program in app0# and attempt to run anything in it kind of like installing a program. must be registered before starting

 

start – starts the program. must be registered to start. you can only you can unregister a program while it has already started but on won’t start on a startup sequence

 

the loading sequence looks for app01-app10 first starting from locations RM, RM2, then internal memory. RM are the USB removable media slots.

 

 

console commands to manage and control your programs

 

PROGREG :: lists all registered programs

 

PROGREG -p:## :: register program ##

 

PROGREG -p:## -u :: unregister program ##

 

APPSTAT :: allows you find which devices (ethernet, cresNet, IR, RF, et al) are being used by which program

 

STOPPROG :: stops all programs in the processor

 

PROGRESET :: starts all registered programs

 